A combination of arcconf 2.02 and an Adaptec 8805 produces a third
subsection under each physical device called 'Runtime Error Counters' which breaks the workaround
for the subsection hash key not being reset

Arcconf output attached, I'll also provide a patch sometime soon that takes into account the medium errors etc in this section for alerting as well

arcconf.txt

A combination of arcconf 2.02 and an Adaptec 8805 produces a third
subsection called 'Runtime Error Counters' which breaks the workaround
for the subsection hash key not being reset
@glensc glensc added the arcconf label Nov 21, 2016
@glensc
Copy link
Owner

glensc commented Nov 21, 2016

the parser should be fixed, as it's not the only place with the workaround.

and you are missing GETSTATUS output. i can not add the output to testsuite. please attach it. please read CONTRIBUTING.md

@glensc glensc merged commit 0dd7570 into glensc:master Nov 21, 2016
glensc added a commit that referenced this pull request Nov 21, 2016
glensc added a commit that referenced this pull request Nov 21, 2016
glensc added a commit that referenced this pull request Nov 21, 2016
@meanphil
Copy link
Contributor Author

meanphil commented Nov 21, 2016

GETSTATUS output attached...