HP Apollo 4510 with the following setup:
- Smart Array P840 in Slot 1 (HBA Mode)
Controller Status: OK
68 x 6TB Disks in HBA Mode - Smart HBA H244br in Slot 0 (Embedded) (RAID Mode)
Controller Status: OK
2 x 800GB Disks in RAID
The execution with debug ON results are:
# check_raid.pl -d
DEBUG EXEC: /proc/mdstat at ./raid.pl line 474.
DEBUG EXEC: /sbin/hpssacli controller all show status at ./raid.pl line 474.
DEBUG EXEC: /sbin/hpssacli controller slot=1 (HBA Mode) logicaldrive all show at ./raid.pl line 474.
DEBUG EXEC: /sbin/hpssacli controller slot=0 logicaldrive all show at ./raid.pl line 474.
UNKNOWN: hpssacli:[Smart HBA H244br: Array A(OK)[LUN1:OK], Smart Array P840: ]
Content of every EXEC:
# cat /proc/mdstat
Personalities :
unused devices: <none>
# /sbin/hpssacli controller slot=1 (HBA Mode) logicaldrive all show
-bash: syntax error near unexpected token `('
# /sbin/hpssacli controller slot=0 logicaldrive all show
Smart HBA H244br in Slot 0 (Embedded)
array A
logicaldrive 1 (838.3 GB, RAID 1, OK)